A Complete Rootzone Analysis will be performed on a 3" core sample which includes a physical analysis, particle size analysis, uniformity coefficient, organic matter analysis, pH, and USGA recommendations for a putting green rootzone mixture (greensmix).
INSTRUCTIONS FOR TAKING UNDISTURBED SOIL CORES
1. Cut 2" PVC pipe into a section long enough to reach a minimum of 3" below the desired test depth or to the gravel layer, if present. The PVC pipe outer diameter must be 2" to fit our equipment. Samples will be tested in 3" layers. Provide duplicate cores, if possible.
2. Sharpen the penetrating end of the pipe.
3. Drill two holes opposite each other near the top of the pipe so that a metal rod can be inserted as a handle for removing the core.
4. Pound the PVC pipe into the green. If greens are old push-up greens pound the pipe as far as it will go.
2. Sharpen the penetrating end of the pipe.
3. Drill two holes opposite each other near the top of the pipe so that a metal rod can be inserted as a handle for removing the core.
4. Pound the PVC pipe into the green. If greens are old push-up greens pound the pipe as far as it will go.
Figure: Pound 2" PVC pipe into the green.
Use the metal bar as a handle to remove the core
Use the metal bar as a handle to remove the core
5. Remove the core, pack each end with paper, tape both ends with duct tape, and pack cores securely for shipping.
6. Send samples to:
Tifton Soil Testing Lab, LLC
689 Brighton Rd
Tifton, GA 31794
Phone: (229) 382-7292
E-Mail: t[email protected]
6. Send samples to:
Tifton Soil Testing Lab, LLC
689 Brighton Rd
Tifton, GA 31794
Phone: (229) 382-7292
E-Mail: t[email protected]