USGA Recommendations
for Gravel When Intermediate (Choker)
Layer Is Not Used
| Performance Factors | Recommendations |
| Bridging Factor | D15 (gravel) ≤ 8 x D85 (rootzone) |
| Permeability Factor | D15 (gravel) ≥ 5 x D15 (rootzone) |
| Uniformity Factors | D90 (gravel)/ D15 (gravel) ≤ 3.0 |
| No particles larger than 12 mm | |
| ≤ 10% particles smaller than 2 mm | |
| < 5% particles smaller than 1 mm |
The 3 - 4" layer of 2 - 9.5 mm Gravel is placed above the drain tile. The 12" Rootzone Mix is placed above the gravel.
|
USGA Recommendations
The 3 - 4" layer of 1/4 - 3/8" Gravel is placed above the drain tile. The 2 - 4" layer of 1 - 4 mm Intermediate (Choker) Layer is placed above the gravel. The 12" Rootzone Mix is placed above the intermediate layer.
Particle Size of USGA Rootzone Mix
Physical Properties of USGA Rootzone Mix
|
||||||||||||||||||||||||||||||||||||||||||||||||
|